Therapeutic Radiologic Technologist
What you'd do
The Therapeutic Radiologic Technologist at the is Level works independently carrying out procedures which have varying assignments. This includes basic and advanced treatment modalities and procedures.
Major duties
Major Duties and Responsibilities include, but are not limited to: Independently conduct daily quality assurance measures, machine warm up procedures, interpretation of output levels compared with established thresholds Ensures all equipment is in safe working order, reporting all equipment problems as appropriate. Provide guidance and direction to lower grade TRTs involving complex treatment and unfamiliar or unusual situations involving complex patient clinical issues. Set-up the treatment room and deliver basic and more advanced radiation treatments on a linear accelerator, as prescribed by the Radiation Oncologist. Maintains supplies for the work areas. Schedule treatments in a manner as to optimize accelerator times while maintaining flexibility for emergency cases. This requires the ability to prioritize scheduled patients as well as the ability to accommodate the emergency patient who may need immediate simulation and treatment. Identifies individual patients (time-out) by the required identification methods set forth by hospital policy and departmental procedures before simulation and each daily radiation treatment is delivered. Educate patient, family, and staff on the administration of ionizing radiation. Has the knowledge of consultations, simulation, and treatment planning and treatment procedures. Imaging: Acquiring and Interpreting the images isocenter port/verification films, KV, MV and Cone Beam, as needed by utilizing the on-board imaging system. Perform imaging as per the Service's Imaging Policy, all imaging requests will be in the Patient's Radiation Prescription. Other duties as assigned. Work Schedule: Monday-Friday 8:00am to 4:30pm Telework: Not Available Virtual: This is not a virtual position. Functional Statement #: 000000 Relocation/Recruitment Incentives: Not Authorized Permanent Change of Station (PCS): Not Authoirized
What you need to qualify
Applicants pending the completion of educational or certification/licensure requirements may be referred and tentatively selected but may not be hired until all requirements are met. Basic Requirements: United States Citizenship: Non-citizens may only be appointed when it is not possible to recruit qualified citizens in accordance with VA Policy. Education. Individuals must have successfully completed a program in therapeutic radiologic technology, evidenced by a certificate or an associate's or higher degree accredited by the Joint Review Committee on Education in Radiologic Technology or other accrediting bodies recognized by the U.S. Department of Education (ED) and the subsequent completion of a 12-month ED accrediting body-approved program in therapeutic radiologic technology. Public Law 97-35 requires that persons who administer radiologic procedures meet the credentialing standards in 42 C.F.R. Part 75. They must have successfully completed an educational program meeting or exceeding the standards described in that regulation and is accredited by an organization recognized by the ED, and be radiation therapists certified by the ARRT in Radiation Therapy (T). Certification. All applicants must be certified in therapeutic radiologic technology by the ARRT in Radiation Therapy (ARRT (T)). (1) All applicants must be certified in therapeutic radiologic technology by the ARRT in Radiation Therapy (ARRT (T)). May qualify based on being covered by the Grandfathering Provision as described in the VA Qualification Standard for this occupation (only applicable to current VHA employees who are in this occupation and meet the criteria). Grandfathering Provision: All persons employed in VHA in this occupational series or in another occupational series that are also performing the duties as described in the qualification standard are considered to have met all qualification requirements for the grade held, including positive education and licensure/certification/registration that are part of the basic requirements of the occupation. For employees who do not meet all the basic requirements required in this standard, but who met the qualifications applicable to the position at the time they were appointed to it, the following provisions apply: Employees in an occupation not requiring a licensure/certification/registration, may be reassigned, promoted or demoted within the occupation. Employees in an occupation requiring a licensure/certification/registration, may be reassigned, promoted up to and including the full performance level, or demoted within the occupation, but may not be promoted beyond the full performance level or placed in supervisory or managerial positions. Employees in an occupation requiring a licensure/certification/registration only at higher grade levels must meet the licensure/certification/registration requirement before they can be promoted to those higher-grade levels. Employees who are appointed on a temporary basis prior to the effective date of the qualification standard may not have their temporary appointment extended or be reappointed, on a temporary or permanent basis, until they fully meet the basic requirements of the standard. Employees initially grandfathered into this occupation, who subsequently obtain additional education and/or licensure/certification/registration that meet all the basic requirements of this qualification standard must maintain the required credentials as a condition of employment in the occupation. NOTE: Each uncertified TRT permanently employed on June 21, 1986, and whose competence in the safe administration of ionizing radiation was affirmed, in writing, by a VA licensed physician not later than January 1, 1987, is considered fully qualified. These employees may be promoted, up to and including the journey level, demoted or reassigned within the GS-0648 occupational series. Any employee initially retained in this manner who leaves this job series loses protected status and must meet the full requirements in effect at the time of reentry. Grade Determinations: In addition to the basic requirements for employment, the following criteria must be met when determining the grade of candidates: Therapeutic Radiologic Technologist, GS-10: Experience: At least one year of experience equivalent to the next lower grade level directly related to the position being filled. In addition to the experience above, the candidate must demonstrate all of the following Knowledge Skills and Abilities (KSA's): Skill in independently performing machine warm up procedures and interpreting output levels compared with established thresholds adhering to the principles of radiation safety and all aspects of quality assurance. Ability to independently perform patient chart reviews using an electronic medical record and the Record and Verify System or other similar treatment delivery systems. Ability to independently perform all basic and complex CT simulations, including independently operating the CT equipment, following directives, designing custom immobilization for reproducible set-ups, obtaining optimal imaging, completing accurate data transfer for treatment planning and providing accurate and precise patient documentation. Ability to utilize a Linac's On Board Imaging system to interpret complex images. Reference: For more information on this qualification standard, please visit https://www.va.gov/ohrm/QualificationStandards/. The full performance level of this vacancy is GS-10. Physical Requirements: Physical aspects associated with work required of this assignment are typical for the occupation, see Duties section for essential job duties of the position. May require standing, lifting, carrying, sitting, stooping, bending, pulling, and pushing. May be required to wear personal protective equipment and undergo annual TB screening or testing as conditions of employment.
Before you apply
Federal applications are different: your resume should be 3–5 pages and mirror the language of this announcement. Read our federal resume guide first — it's the #1 reason qualified people get screened out.
Don't miss the next one.
Get an email the moment a similar federal job opens — postings can close in as little as 5 days.